radiology test

Terms

undefined, object
copy deck
for denser areas you'd
increase kVp
the intensity of the beam is
the quality X the quanity divided by the product of area and exposure time =intensity of beam
ampere
measures current flow
PID
position indicating device, the open ended cylinder
smallest particle of a substance that retains the properties of the substance
molecule
mA dial determins
# of x-rays produced by contolling the heating in the tungsten filament to produce electrons at the cathode of the tube
if machine has rotating anodes what is mA range
50-100mA
lead diaphragm
collimating device-restricts the size and shape of the x-ray beam as it leaves the tube head
the x-ray machine keeps from over heating by
duty cycle and duty rating, milliamerage should not exceed 15, rotating anodes are utilized in exraoral radiography, the copper sleeve surrounds the target
half-value layer
x-ray beam penetration(quality) emitted from the tube, it is defined as the thickness of the aluminum that will reduce the intensity of the x-ray beam by 50%
40-65 kVp would__________and below 40kVp would
40-65 would penetrate but have secondary radiation below 40 not enough penetration
Radiation
the emission and propagation of energy through space or a substance in the form of wave particles
kVp range is
65-100 kVp (65,000 V, 100,000 V)
cycle
flow and reversal of current
characterisitic x-rays
70 kVp or above
the normal HVL for a dental x-ray beam is about
2.75 mm of aluminum
which electrons have the greatest binding energy?
k shell electrons
filtration
removes long wave lengths
what is the purpose of the collimating device
restricts the size and shape of the x-ray beam as it leaves the tube head. Circular collimation allows a margin of error in the film alignment
when was x-ray discovered
Nov. 8,1895
scatter radiation
radiation that when passing through a substance has been deviated in direction (pointed cone)
what is the total filtration needed for machines operating UP TO 70 kVp
1.5 mm total filtration is required
what is the total filtration for machines operating at 70 kVp or HIGHER
2.5mm total filtration is required
kilovoltage
the quality of x-rays (or penetrating power)
kVp above 100 would cause
overpenetration
what is the intensity of the beam affected by
kilovolt peak (kVp), milliamperage(mA), exposure time and focal-fim distance (FFD)
rectangular collimation
is comparable to the size of a #2size film packet
the person accredited with the initial discovery of x-ray
Wilhelm Conrad Roentgen
the hotter the resistant filiment becomes the more electrons are produced at the ________
cathode
miliamperage control
quanity of x-rays
mA higher than 15 would
produce to many electron=to much heat
useful beam
x-ray beam after collimation and filtration
ionization
loss of an electron
an example of particulate radiation is
electrons, beta protons, protons, neutrons, alpha particles
thermionic emission effect
production of free electrons by the passing of an electric current through a tungsten filament with resultant heating of the filament (electron cloud)
rectification
current reversal blocking-the blocking of the flow of one current in one direction in an alternating current circut
impulse
1/60 of a second
electricity
energy source used for radiation production
the PID's should be __, __,or __ inches long
8,12 or 16 inches long
what is the range on machines for mA
5-15 mA
bremsstrahlung
"breaking radiation" the slowing down and veering off course of the entering high speed electron with loss of energy expressed in x-rays