Basic Damage Control
Terms
undefined, object
copy deck
- How many fire pumps are on the GW?
- Twenty Two
- The compartment numbering system used onboard the GW consists of how many parts?
- Four
- what is the most important issue in controlling flooding?
- Hold what you have and prevent progressive flooding
- How can flooding water be removed from the GW?
- Installed drainage systems: main, secondary, & miscellaneous drains Portable Equipment P-100 pump, Eductors: Peri jet, S-type, Submersible pumps; Bucket & Swab
- What does the term progressive flooding mean?
- Water that continues to spread from one compartment to another unchecked
- What repair locker is designated secondary DC Central?
- Repair three
- What does the term flooding mean?
- The unplanned introduction of water into the ship
- Using the given example 3-75-4-M state what each letter and number means.
- 3-Third deck, 75-fwd most frame in the compartement, 4-the second compartment from the centerline on port side, M-Magazine
- How many fire pumps onboard the GW are steam powered?
- Four
- What makes underwater battle damage more dangerous than above water damage?
- Reduction of stability due to flooding
- Where are secondary fire booundaries establishes in relation to the primary fire booundaries?
- The first transverseee watertight bulkhead foward and aft of the primary fire boundaries
- What are three types of heat transfer?
- Radiation, convection, conduction.
- What is the best extinguishing agent for a class "D" fire?
- Very large amounts of water either by high or low velocity fog
- How many fire pumps are onboare the GW are electric powered?
- Eighteen
- What is the J-dial number used to report casualties?
- 911
- What is the best extinguishing agent for a class "B" fire?
- Halon, AFFF, PKP
- Where the ships emergency phone number ring at sea?
- DC Central & the Bridge
- What are the three components of the fire triangle?
- Fuel, Heat, & Oxygen
- White smoke would indicate what type of fire is burning?
- Class Alpha fire
- How many major repair lockers are there onboard the GW?
- Ten
- A class Bravo fire involves the burning of wat materials?
- Fuel
- Black smoke is an indicator of what type of fire?
- Class Bravo fire
- What is the best extinguishing agent for a class "C" fire?
- Carbon Dioxide (CO2)
- What calss of fire produces ash?
- Class Alpha fire
- Where the ships emergency phone number ring inport?
- Quarterdeck & DC Central
- The burning of electrical material is involved in whatclass of fire?
- Class Charlie fire
- Blue smoke is an indicator of what class of fire?
- Class Charlie fire
- What is the purpose of M-291 kit?
- Personnel Decontamination
- What is the best extinguishing agent for a class "A" fire?
- High velocity or low velocity fog
- Thick black smoke indicated what type of fire?
- Class Delta fire
- What burns during a class delta fire?
- Special hazard & burning metals
- How many unit lockers are onboard the GW?
- twenty five
- Where is DC Central located?
- 4-119-0-C
- What RADIAC instrument is designed for shipboard installation or portable operation?
- AN/PDR-65
- What equipment is recommended for dewatering compartments containing debris?
- Peri jet eductor
- what chemical agents cause such temporary discomforts as vomiting, coughing, nausea & tearing?
- Incapacitating Agents or Riot Control Agents
- What nuclear blast causes the greateest contamination?
- Surface Blast
- What is the last article of protective clothing you would remove when passin through a personnel decontamination station?
- protective mask
- what is the primary use of the expolsimeter?
- To detect explosive gases
- what is the maximum number of casualty power cables that can be rigged to Brisket terminals?
- Three
- What is the pproper method of connecting casualty power?
- Start at the unit to be energized and work toward the source of power
- What is the purpose of rigging jumper hoses?
- Restoring salt water services to damaged areas
- Wheere does the countermeasure washdown system get its water supply?
- Firemain System
- What type of firefighting breathing apparatus is currently in use?
- SCBA- Self Contained Breathing Apparatus
- AFFF is the primary extinguishing agent for what class of fire?
- Class bravo fire
- What is the purpose of the primary purpose of the electrical submersible pump?
- Dewatering fluids free of heavy oils and large objects
- what is the standard size eductor discharge hose and overboard connection?
- 2 1/2" up to 4"
- What size SCBA cylinders do we have?
- 45 min & 30 min
- what is the primary purpose of the eductor?
- Pumping contaminated liquids
- What is the primaary use of PKP?
- Extinguishing Class "B" fires
- Who is in charge at the scene of a fire?
- The On Scene Leader
- What does a class "D" fire involve?
- Special hazards & burnable metals
- When using a PKP to fight a class "B" fire what part of the fire tetrahedron is being inhibited or eliminated?
- the chemical chain reaction
- What does a class "B" fire involve?
- Flamable liquids
- What does a class "A" fire involve?
- Ordinary combustibles that leave an ash
- Which pricnipal of heat transfer involves direct contact?
- Conduction
- What should be secured when isolating a fire area?
- Doors, hatches, ventillation, and electrical power
- When over hauling a class "C" fire who assists the electrician?
- Overhaulman
- Which principal of heat transfer involves the movement of air?
- Convection
- What equipment is required for the firefighters to enter a burning compartment?
- SCBA, fire fighting helmet, anti-flash hood, fire fighting gloves and an "FFE" in "B" fires.