APP Limits
Terms
undefined, object
copy deck
- APP Light Off
- 20%
- APP Clutch Engagement
- 82-88%
- APP normal Hang-Up time
- 2-4sec
- APP total start time
- 15sec
- APP EGT must be no more than ___ for start
- 200
- APP Max EGT
- 621
- APP Normal RPM
- 102.5+/-.5
- APP Max RPM
- 110
- APP will operate up to what PA?
- 10,000
- APP fuel burn rate
- 100pph
- APP burns from which tank
- right main
- APP Accumulator Charge
- 3000psi
- APP Accumulator Charge for cold weather (below -25F)
- 4000psi
- APP What protection is active prior to 92%
- High EGT
- APP What protection is active after 92%
- High EGT/Low Oil Pressure
- APP The Emergency Start Switch bypasses what protections?
- High EGT/Low Oil Pressure
- APP When must you abort an APP start?
-
Hang Up >5sec
No EGT
No RPM
Doesn't automatically shutdown above 621