- 1. (201) What does the Defense Energy Support Center (DESC) determine the type, size, and numberof fuel tanks needed at each base based on?
- The mission requirements.
-
2. (201) What will horizontal underground storage tanks and cut and cover tanks that issue jet fuel
have on top of them?
- A pumphouse.
- 3. (201) All new tanks must have what kind of containment?
- Double-wall construction or a dike
- 4. (201) What should you use when replacing a manway cover?
- A new gasket the same thickness as the old one
- 5. (201) Damage to a tank can occur if the
- Vent or vent piping becomes clogged
- 6. (202) Which type of aboveground tank can withstand very little pressure or vacuum during the filling or removal of fuel?
- Cone roof.
- 7. (202) The product withdrawal line terminate inside a cone roof tank with a floating pan in a
- vertical position, 6 inches above the top of the sump
- 8. (202) What size is the water draw-off line in an all weather tank, and where does it terminate?
- ¾ inch, ½ inch from the sump bottom
- (202) In the northern hemisphere, which way will the inlet line on an all-weather tank cause the fuel to rotate, and what degree is the line turned?
- Counterclockwise, 60ï‚°.
- (202) At what level does the high-level alarm actuate on a cone roof with floating pan?
- Just before the high-level shut-off level
- (202) What level above the tank bottom is the low-level shut-off set at on a 25,000 bbl cone roof tank with floating pan?
- 27 inches.
- 12. (202) At what level are the support legs on a cone roof tank with floating pan set at for day-to-day business?
- 3 feet
- 13. (202) What type of vent is located on a floating pan?
- Bleeder.
- 14. (203) The wind girder is installed on floating roof tanks to
- prevent the collapse of the tank shell.
- 15. (203) The roof guide is installed on floating roof tanks to
- keep the roof from rotating.
- 16. (203) The double-deck floating roof tank is the most efficient type of roof because the roof
- has insulating air space between decks.
- 17. (204) About how far above the tank floor is the first stage of the deep-well turbine pump located?
- 6 inches.
- 18. (204) What size is the cleanout line on an underground tank, and where does it terminate outside the tank?
- ¾ inch, 12 inches above ground level
-
19. (205) You must clean a bulk storage tank that has a receiving filter separator and is internally
coated every
- 8 years.
- 20. (205) You must clean an operating storage tank that does not have a receiving filter separator but has internal coating every
- 6 years.
-
21. (205) You must clean an operating tank that is not internally coated and does not have a receiving
filter separator every
- 4 years.
- 22. (205) How often do you clean a Mogas or diesel tank?
- By direction of the fuels management office
- 23. (205) How is the product identification displayed on an aboveground tank?
- Yellow bands with white letters on a black background
- 24. (205) How many bands are used to identify JP–8 fuel?
- Three
- 25. (206) The fuse link on a fuse link valve used on a cone roof tank will normally melt at what temperature?
- 160° F.
- 26. (206) When manually gauging a tank, why must you keep the tape in contact with the gauge pipe?
- To prevent the discharge of a spark.
- 27. (207) When the roof supports on a floating roof tank are in the UP position, at what level will the roof rest above the floor?
- 3 feet.
- 28. (207) At what level must the automatic bleeder vent supports be set when preparing for an internal inspection and cleaning?
- 6 feet.
- 29. (207) What prevents fuel from entering a roof drain line?
- Flange gaskets and asbestos ring packing.
- 30. (207) In extremely cold climates, what should you do to the roof drain line?
- Fill it with 50/50 mix of antifreeze and water
- 31. (207) What is the inspection frequency for the fabric seal on a floating roof tank?
- Monthly
- 32. (207) When filling the tank to check the high-high-level alarm, what must be disabled?
- The high-level alarm.
- 33. (208) What would you use to check the liquidometer accuracy?
- Tape and bob.
- 34. (208) How would you take care of internal corrosion for the low-level control attached to the liquidometer?
- Wire brush clean and replace the cover gasket.
- 35. (209) How long before entering a fuel tank must you request permission from your MAJCOM?
- 15 workdays.
- 36. (209) Who will assign a qualified tank entry supervisor to supervise a tank cleaning operation?
- MAJCOM fuels engineer.
- 37. (209) Which one of the following is not the responsibility of the MAJCOM fuels engineer’s representative during the contract cleaning of a fuel tank?
- To stop the contractor’s work for contract violations.
- 38. (210) Which of the following fuels normally contains a higher concentration of benzene?
- Gasoline.
- 39. (211) During tank cleaning, when should you remove heavily contaminated clothing?
- After being drenched with water.
- 40. (211) Communication gear must be used during the cleaning of an underground JP–8 tank when the
- manhole access is 12 feet below ground level.
- 41. (211) All electrical equipment to be used within 50 feet of any fuel system must be defined as which class in the National Electrical Code?
- Class I, Division I, Group D
- 42. (211) A safety harness, used in tank cleaning, is good for a maximum of how many years from the date stamped on the harness?
- 10.
- 43. (212) Artificial lights, other than battery-powered safety lanterns, can be used only during tank cleaning after what condition is met?
- The tank is vapor free
- 44. (212) During initial cleaning, at what percent of the lower explosive limit (LEL) must you suspend washing down a tank?
- 20
- 45. (212) At what vapor level may workers initially enter a tank for tank cleaning?
- Below 10 percent LEL.
- 46. (212) During tank cleaning, how often must you record a vapor reading?
- Every 15 minutes.
- 47. (212) When can people enter a fuel tank without protective equipment?
- c. 0 percent LEL, the tank has been washed out and dried, the tank is known never to have contained leaded fuel, and the Bioenvironmental Engineer has approved their entry
- 48. (213) What must be done to fuel pumps and motors located in a pit if they are to be abandoned?
- Removed and stored in a dry place.
- 49. (213) What must be done to meters in a pit that is to be abandoned?
- Drained, removed, oiled, and placed in storage.
- 50. (214) How do you reset the lower explosive limit (LEL) sensor on the MultiRAE PGM–50?
- Sample fresh air for 60 seconds then press the “Y/+†button
- 51. (214) What is the minimum recommended voltage for the MultiRAE PGM–50?
- 4.4 volts.
- 52. (215) What should you do if the restriction indicator on a MC–7 air compressor is tripped?
- Clean the air filter element.
- 53. (216) Electrical controls in hazardous areas must be proofed (protected) against
- explosion.
- 54. (216) The Class I, Division 2, hazardous area around a service station dispenser extends outward how many feet and upward how many inches?
- 20 feet, 18 inches.
- 55. (216) What type of electrical units and wiring is used in non-hazardous locations, such as pressurized control rooms?
- General purpose, enclosed type.
- 56. (216) What type grounding rod, if any, is used on a horizontal fuel tank installed under the pumphouse floor?
- Not required.
- 57. (217) What will change positions and to what valve will pressure be directed when the float of the pilot valve assembly is in the TOP position?
- Rotary disc; fuel discharge valve.
- 58. (217) When the float in a vertical filter separator rises to the top position, what happens?
- The fuel discharge valve closes.
- 59. (218) How are the coalescers and separators mounted in an API 1581 filter separator?
- Coalescers at the bottom and separators at the top
- 60. (218) Coalescers in an API 1581 filter separator are rated for what minimum gallons per minute (gpm) per inch of length?
- 2.27.
- 61. (219) When the water drain valve is removed from the filter separator, where is the control tubing that once went to the water drain cover chamber rerouted?
- Nowhere, it is plugged off.
- 62. (219) When the float in a filter separator is in the top position, to what component is pressure applied to close 40AF–2C fuel discharge valve?
- Three-way control valve.
- 63. (220) If a fuel system has a maximum deadhead pressure of 125 pounds per square inch (psi), at what psi should the filter/separator pressure relief be set?
-
137.5
- 64. (220) When removing the KMU–416/F modification kit with 9 additional elements, how many elements must you remove from the front side to balance the manifold?
- 6.
- 65. (220) When gravity-filling a horizontal filter/separator from another horizontal filter separator, how many minutes must you wait for the two filter separators to equalize?
- 10.
- 66. (220) If the 40AF–2A, fuel discharge valve, fails to open, what should you check first?
- Water in the filter/separator.
- 67. (221) What type of strainer is normally used as a line strainer in a pipeline?
- Cylindrical
- 68. (222) What is the most probable cause for a meter to over-register?
- Air in the line.
- 69. (222) How is the register of a meter changed to match the actual fuel dispensed through the meter?
- Change the gear train ratio.
- 70. (223) What maintains a tight seal in the measuring chamber of an A. O. Smith meter?
- Teflon vane inserts.
- 71. (223) Who should do the repairs when an A. O. Smith meter requires major maintenance?
- Manufacturer.
- 72. (224) The liquid control meter uses what type of movement to register the fuel?
- Blocking rotor and two displacement rotors.
- 73. (224) Leakage inside the back of a liquid control meter is caused by a faulty
- O-ring.
- 74. (225) If you changed the Brodie coarse adjustment one position, what change would be made to the register reading?
- 6 gallons per 1,000 gallons.
- 75. (226) How many hoses does a master meter have and where are they connected?
- 2 hoses; outlet side.
- 76. (227) What type of tank gauge can test a tank for leaks?
- Magnetostrictive probe.
- 77. (228) A differential pressure gauge installed on a filter/separator measures the difference between the inlet
- high pressure and the outlet low pressure.
- 78. (229) At a minimum, how often are simple pressure gauges calibrated?
- Annually.
- 79. (230) Tank truck unloading headers will be spaced about how many feet apart?
- 60.
- 80. (231) The emergency-stop switches have what type of contacts and complete which circuits?
- b. Closed; low-voltage for the fuel transfer pump control
- 81. (231) Emergency-stop switches are what color?
- Red.
- 82. (232) What type of grounding rods are used on aboveground fuel tanks?
- Galvanized steel.
- 83. (233) An impressed-current cathodic protection system uses anodes made of
- carbon.
- 84. (233) What do unaccountable fluctuations of the rectifier in a cathodic protection system indicate?
- Stray-current activity.
- 85. (234) When receiving fuel by pipeline, what is the first component that fuel passes through at the bulk storage area?
- Pressure reducing valve.
- 86. (234) What is the minimum speed for a scraper when cleaning a pipeline?
- 2 mph.
- 87. (235) How many storage tanks would normally be used at an automotive service station that offers MOGAS, and diesel fuel?
- 1 for each product.
- 88. (235) For safe dispersal of fuel vapors, a storage tank vent pipe must extend how high?
- 12 feet
- 89. (235) What type of valve is found on the suction line, inside the tank, if the fuel dispensing units are self-contained?
- Foot valve.
- 90. (236) What is the difference between the motors used in the self-contained single dispensing and the dual dispensing units?
- Dual dispensing motors have a higher horsepower rating.
- 91. (237) You have replaced the pump head of a dispenser pump but the pump still binds. What can you do to solve the problem?
- Increase the number of gaskets used under the head, one at a time, until the pump is free.
- 92. (238) The drive shaft on a three-piston vertical positive displacement meter will make how many revolutions for each gallon of fuel delivered?
- 4.
- 93. (238) The correct position of a dispenser meter cover is determined by
- a dowel pin in the top flange of the cylinder body and a locating hole in the cover flange
- 94. (238) If the meter register on a dispenser does not reset to zero or the numerical wheels do not turn during delivery, the probable cause is a
- broken shear pin.
- 95. (239) What should the vacuum reading be on a normal self contained dispenser pump installation?
- 4 to 6 inches
- 96. (239) To check for sufficient pump pressure on a self-contained dispensing unit, where should you install the pressure gauge?
- On top of the meter cover.
- 97. (239) The self-contained dispenser pump regulating valve is functioning properly when a pressure gauge is reading
- 18 psi one hour after the pump is turned off.
- 98. (240) If an automatic shutoff nozzle shuts off all the time, what is the first thing you should check?
- Vacuum tube.
-
99. (241) How many selectable fuel product pumps does each master vehicle identification reader(MVIR) have the capacity to control?
- 8.
- 100. (241) The purpose of the manual override switch on a vehicle identification reader (VIR) is to
- allow you to enter the vehicle identification link (VIL) code from the panel.
-
(The right one) 32. (207) When filling the tank to check the high-high-level alarm, what must be disabled?
- The high level shut off valve