Replaceable components in Power Distribution Panel
Equipment and Antenna CB fuses (3 each)
Frequency of the standby trigger source in SHORT PULSE (SP) mode?
800 mHz
the TRANSMITTER produces...
VERY HIGH VOLTAGES, CURRENT,& MICROWAVE RADIATION LEVELS
Receives and detects weak echo pulses, amps them, & routes them to display
RECEIVER
operator controls on the Master Display Unit
short/long pulse, antenna ae control, gain, stc, ftc, rings
Antenna simulates...
TRANSMITTING and RECEIVING of RF energy
Antenna CB
provides power for antenna
Equipment CB
provides power for the MDU, RCP, & Tx/Rx
DS5
illuminates when 115 VAC is present in LVPS
proper hand tool selection
avoids stripping of threaded hardware, snapping heads off bolts that are associated with mounting brackets
elapsed time/12.36 uSec
Range
(PW + recovery time) x 164 yds
MIN Range
PRT/12.36 uSec
MAX Range
PW x 164 yds
Range Resolution
1.25 x (square root)antenna height (ft)
Radar Horizon
Replaceable components in MDU
LVPS, Backplace Interface Panel, TX Ready LED (standby)
Replaceable components in RCP
Fuses on UPS, Coax cables on rear panel, antenna contactor assembly
Replaceable components in Tx/Rx
Cabinet Interlock, Local Oscillator, Magnetron, Modulator, Modulater Control PCB, PRF sync/gen PCB, Receiver AFC module, Waveguide, Power Supply
Replaceable components in Antenna
Antenna Encoder PCB
Frequency of the standby trigger source in LONG PULSE (LP) mode?
400 mHz
Azimuth Counter Pulse (ACP) used for...
sweep
Azimuth Reference Pulse (ARP) used for...
showing when the antenna is at 0° bearing
Two test points used to troubleshoot the antenna
J3 and J4 on PCB 3A6
Two signals compared and output to the Local Oscillator Mixer
Aimed Frequency 60 MHz and IF Signal
Internal power for the RCP is provided by...
Universal Power Supply
Two modes AP radar can be powered on...
Local & Remote
Mode of energizing often used for preventive or corrective maintenance
LOCAL
Local ON is passed to...
PCB and Indicator Assembly
allows the passing of 440VAC to antenna drive circuits...
Local AE Control